AKCess Pro Dry Contact Sensor

The Dry Contact sensor from AKCP is a simple connection to burglar alarms, fire alarms or any application that requires monitoring by the sensorProbe or securityProbe remote monitoring appliances.

Dry Contact Sensor from AKCP

Dry Contact sensor with an ALARM/NORMAL indication in software. Can have an unlimited number of dry contacts sensors. Dry contact sensors are user definable and can be used to detect many different inputs such as UPS status, security systems, air conditioning status.

SNMP interface for alarm/normal status. SNMP traps sent when critical. SNMP polling via get available. Web browser interface available. When an alarm condition is activated the description and location of the fault can be sent via email, page.

Forwarding of alarms via email, SMS or SNMP trap

The via potential-free contact / alarm contact reported to the network-based AKCP monitoring device alarms of important installations can be routed via text message or SNMP trap to the competent security staff or even to system monitoring solutions by email.

Integration of plant signaling contacts in NMS

The sensor potential free contact has an OID, which enables direct status query of the alarm contact via SNMP command over the network.

In addition, you can integrate the signaling contacts of your business-critical systems in network monitoring solutions / NMS.

Compatibility Sensor floating contact

The AKCP Dry Contact Sensor / potential-free contact is compatible with the sensor and securityProbe measuring devices our partner AKCP.

The connection of the sensor to the sensor port of the IP-monitoring hardware is made by RJ-45 connector.

AKCP AutoSense functionality

The Dry Contact Sensor / AKCP floating contact provides for the purpose of automatic identification of the sensor by the AKCP IT monitoring hardware an autosense function.

Per Disconnect alarm will immediately be notified as soon as the signal contact sensor has been disconnected from the AKCP alarm hardware.


AKCP Dry Contact Sensors

 

The Dry Contact sensor is a simple connection to burglar alarms, fire alarms or any application that requires monitoring by the AKCP sensorProbe monitoring device. Dry contact sensors are user definable and can be used to detect many different inputs such as UPS status, security systems, air conditioning status.

 

from 35,00 Euro*

 

Monitoring System 100 III - buy now

 

The advanced monitoring system 100 III is the entry level model of the high-end surveillance systems from Didactum. This monitoring appliance is designed and manucactured within the EU. The engineering and support of the Didactum monitoring systems are located in Germany.

 

from 239,00 Euro*

 

Specifications

  • Measurement range - Alarm or Normal
  • Measurement rate - multiple readings every second
  • Communications cable - RJ45 jack to sensor using UTP Cat 5 wire
  • Sensor type - open/closed contact switch
  • Input voltage range. 0 to 5 volts
  • Normal input voltage is settable under software
  • Normally open, normally closed is settable under software
  • Current Range. Can sink up to 20 mAmps.
  • Power source: powered by sensorProbe. No additional power needed
  • auto detection feature
  • disconnect alarm